Find the fault by what you can see and hear, not by guessing. A symptom index to thirteen diagnostic guides, with the urgency of each and the first check to make.
Most fault-finding starts in the wrong place. People search for a component — "float switch", "impeller", "non-return valve" — when what they actually have is a symptom: the pump is not running, or the tank is filling, or there is a smell.
This page is organised by what you observe. Find the symptom, follow the guide, and check the urgency before you start.
Every guide below applies to a sewage pump station of any make. Fault finding on a sewage pumping system is not brand-specific: a blocked impeller or a stuck float behaves the same way whatever is printed on the lid.
Before anything else: if water is escaping or the level is rising, isolate the power and stop using the fixtures served by the station. Diagnosis can wait; a flood cannot.
Start here: three questions
| Question | If yes | If no |
|---|---|---|
| Is the tank level high? | The pump is not keeping up — go to section B or C | The fault is control or nuisance — go to section E |
| Is the pump running? | The fault is in the hydraulics or the control — section B or C | The fault is electrical or mechanical — section A |
| Is water returning after the pump stops? | Non-return valve — section D | Continue below |
Those three answers place you in one of five groups. Everything else follows.
A. The pump does not start
| Symptom | Likely cause | Guide |
|---|---|---|
| Nothing happens at all; no sound | No power, isolator off, float not calling | Sewage pump not starting |
| Hums but does not turn | Capacitor, start winding, or a jammed impeller | Impeller jammed |
| Starts, then trips immediately | Electrical fault, insulation, wrong wiring | Tripping the circuit breaker |
| Runs a few minutes then stops | Thermal overload — the pump is protecting itself | Overheating and cutting out |
| Starts when you lift the float by hand | The float is stuck or set wrong | Float switch stuck |
Urgency: high if the tank is filling. A pump that will not start is the fault most likely to end in a flood.
First check: is there power at the isolator, and does the float call for the pump? Those two answer half of these cases.
B. The pump runs but the water does not move
| Symptom | Likely cause | Guide |
|---|---|---|
| Runs, no flow, normal current | Blocked discharge or a closed valve | Runs but does not pump |
| Runs, no flow, low current | Air lock or dry running | Runs but does not pump |
| Runs, no flow, high current | Mechanical binding or a duty point beyond the curve | Impeller jammed |
| Reduced flow, pump labours | Partial blockage, worn impeller | Blocked by wipes |
| Flow far below rated, motor sounds normal | Wrong rotation on a three-phase unit | Runs but does not pump |
Urgency: medium. The tank is filling, but you usually have time to diagnose properly.
First check: clamp the current. Normal current with no flow means a hydraulic blockage; low current means air or dry running; high current means mechanical.
C. The pump will not stop, or starts too often
| Symptom | Likely cause | Guide |
|---|---|---|
| Tank empty, pump still running | Level control failed — float stuck up, welded contacts, stuck contactor | Keeps running after emptying |
| Tank not empty, pump running | The pump is not delivering — see section B | Keeps running after emptying |
| Empties, refills, repeats within minutes | Water returning down the discharge | Water coming back up |
| Cycles many times an hour | Float differential too narrow, or tank too small | Short cycling |
| Runs continuously, never catches up | Inflow exceeds the pump, or a leaking fixture | Keeps running after emptying |
Urgency: high for the empty-tank case — a pump running dry destroys its seal within minutes. Isolate first, diagnose second.
First check: is the tank actually empty? That one observation splits this whole group.
D. Water comes back
| Symptom | Likely cause | Guide |
|---|---|---|
| Level rises in the tank after the pump stops | Non-return valve not seating | Water coming back up |
| Water at a floor drain or shower tray | System pressure, backflow level | Water coming back up |
| Water at the lid or a joint | Gasket, inlet seal or cable gland | Water coming back up |
| Tank rises with nothing in use | Hidden inflow — leaking cistern, groundwater | Water coming back up |
Urgency: medium to high, depending on where the water is appearing. Water at a floor drain in a basement is a contamination issue, not just a wet floor.
First check: mark the tank level after the pump stops and look again in ten minutes.
E. Smell, noise or alarm
| Symptom | Likely cause | Guide |
|---|---|---|
| Sewage smell in the room | Trap siphoned, vent missing or wrongly terminated | Why does my station smell |
| Smell only after the pump runs | Vent blocked or undersized | How to vent a station |
| Humming | Motor or capacitor | Pump making noise |
| Grinding or scraping | Impeller rubbing, bearing failure | Pump making noise |
| Rattling | Loose component or debris in the tank | Pump making noise |
| Bang on pump stop | Water hammer — valve closing too fast | Pump making noise |
| Alarm sounds, level normal | Alarm float stuck, set too low, or wet wiring | Alarm keeps sounding |
| Alarm sounds, level high | A real alarm — the pump is not keeping up | Alarm keeps sounding |
Urgency: smell and noise are usually not emergencies but indicate a developing fault. An alarm is different — look in the tank before you silence it.
Symptom-to-urgency summary
| Symptom | Urgency | First action |
|---|---|---|
| Water escaping the tank | Immediate | Isolate power, stop using fixtures |
| Pump running with an empty tank | Immediate | Isolate power — dry running destroys the seal |
| Pump will not start, tank filling | High | Check power, then the float |
| Alarm sounding, level high | High | Stop using the fixtures, check the pump |
| Water returning after the pump stops | Medium | Mark the level, check in ten minutes |
| Short cycling | Medium | Count the starts, time a run |
| Smell in the room | Medium | Check the trap, then the vent |
| Noise | Low to medium | Identify the sound type |
| Nuisance alarm, level normal | Low | Check the alarm float and wiring |
When to stop diagnosing and call someone
| Situation | Why |
|---|---|
| You have isolated the power and cannot find the fault | Guessing at electrical faults is how people get hurt |
| The pump has tripped thermal protection more than twice | Each cycle damages the winding |
| There is water where it should not be, and it is rising | Damage limitation beats diagnosis |
| The fault has recurred three times | The specification is wrong, not the component |
| You cannot reach the impeller safely | Confined space, sewage, no PPE — stop |
A fault that recurs is not a fault. It is a specification problem, and it needs a different answer than another repair. If the same station blocks or trips every few months, the free passage or the tank volume is wrong.
Working on a real project?
Send the fixture list, not the model code
Send the fixture list, required lift height and supply voltage. We will recommend the matching model from the 2026 catalog.
FAQ
Where should I start when a lifting station fails? Three questions: is the tank level high, is the pump running, and is water returning after it stops. Those three answers place you in the right group.
What is the most urgent fault? A pump running with an empty tank. The mechanical seal is cooled and lubricated by the pumped liquid, and it can be destroyed in minutes. Isolate the power first.
Why does the same fault keep coming back? Usually because the cause was treated rather than the specification. Repeated blockages mean free passage is too small; repeated overheating means the duty point is wrong; repeated float failures mean the float is undersized for the switching current.
Can I reset the thermal overload and carry on? You can, and it will trip again. Each reset is another heat cycle on the winding. Find the cause before resetting a third time.
Next step
If the fault has recurred and a repair has not held, describe what keeps happening and what was found. We will tell you whether the station suits the duty — which is a different question from whether the pump works.
Request a quotation · Maintenance schedule · See the range
Related reading
- Sewage pump not starting — eight causes, in the order worth checking
- Sewage pump runs but does not pump — the pump is working, the water is not moving
- Sewage pump blocked by wipes — the most common blockage in domestic duty
- Sewage pump impeller jammed — the two-minute test that separates jam from blockage
- Lifting station alarm keeps sounding — when the alarm is the fault and when it is the messenger
- Sewage pump short cycling — a fault that damages the motor while working correctly
- Sewage lifting station maintenance schedule — what prevents most of the faults above