A high-level alarm means either the level really is high or the alarm float is lying. One look in the tank separates them. What each alarm type means and what to do.
An alarm on a lifting station is almost always a high-level alarm: a float set above the normal start level has risen, which means the pump has not been keeping up. That is the design intent. The alarm exists because the next thing to happen, if nobody acts, is sewage on the floor.
So the first action is not to silence it. It is to look in the tank.
- Level genuinely high → the pump is not working, or not keeping up. Real alarm.
- Level normal, alarm still sounding → the alarm float or its circuit is faulty. Nuisance alarm.
That single observation decides everything that follows. Silencing the alarm first removes the only warning you have.
What each alarm is telling you
Not every station has every type, but these are the common ones.
| Alarm type | What triggered it | What it means |
|---|---|---|
| High level float | Level reached the alarm float | Pump failed, blocked, undersized or not running |
| Thermal / overload | Motor protection opened | Pump overheated — see overheating |
| Seal / moisture sensor | Water detected in the oil chamber | Mechanical seal has failed; pump needs attention soon |
| Power failure | Supply lost | Pump cannot run; tank will fill |
| Phase failure (three-phase) | One phase lost | Motor will not start, or runs hot |
| Run-dry protection | Level fell below the motor | Pump stopped to protect itself |
The seal alarm is the one most often ignored, and the one with the clearest warning. It fires before the motor is damaged, which is exactly when a seal replacement is cheap.
Real alarm: the level is high
Work through this in order. Speed matters — the tank is filling while you diagnose.
- Is the pump running?
- No → go to step 2.
- Yes, but not emptying → the pump is running but not delivering. See runs but does not pump.
- Is there power? Check the isolator, the breaker and any RCD. A tripped breaker is a symptom, not the fault — see tripping the circuit breaker.
- Is the float calling for the pump to run? Lift it by hand. If the pump starts, the float was stuck or set too high.
- Is the pump jammed? Isolate and try to turn the impeller by hand. See impeller jammed.
- Is the discharge blocked? Check valve positions first, then the pipe.
- Is the inflow simply too much? If the pump runs continuously and the level still rises, the inflow exceeds the pump. That is a sizing problem, not a fault.
If you cannot stop the inflow, the priority changes from repairing the pump to limiting the damage: stop using the fixtures, and if the tank has a manual discharge or a spare pump connection, use it.
Nuisance alarm: the level is normal
The alarm float has been triggered without a genuine high level. Four causes.
| Cause | How to confirm |
|---|---|
| Float stuck in the raised position | Lift and release it — it does not drop |
| Float set too low | Alarm fires at a level the pump handles routinely |
| Float fouled on pipework or the pump cable | Float visibly trapped or held at an angle |
| Water or condensation in the float or junction box | Water inside the float body; corroded terminals |
| Loose or corroded alarm circuit wiring | Alarm intermittent, especially in damp weather |
| Control panel fault | Alarm latches and will not clear after the float drops |
| Alarm float fitted below the start float | Alarm fires every cycle |
The float set too low is a design error rather than a fault, and it is common after a station has been serviced and the floats repositioned by eye. The alarm float must sit above the start level by enough that the pump has a chance to respond — typically 100–150 mm above the start point, and always below the inlet.
Correct positioning is in how to set float switch height.
A float full of water sinks instead of rising, which produces the opposite fault — the alarm never fires. A float that has lost buoyancy should be replaced, not dried out.
Why the alarm keeps coming back
If the alarm sounds, is cleared, and returns within days, one of three things is happening.
The underlying fault was never fixed. A pump that was freed from a jam but not inspected will jam again. A seal alarm that was reset will fire again at the next cycle.
The pump is marginally undersized. It copes in dry weather and cannot cope when there is more inflow — a wet week, a full house, a leaking cistern adding a constant trickle. The alarm is correct and the pump is the problem.
The alarm circuit itself is marginal. Corroded terminals in a damp chamber produce intermittent alarms that no amount of pump servicing will stop. Check the wiring, not the pump.
What not to do
Do not disconnect the alarm. It is the only thing standing between a failed pump and a flooded basement. If it is a nuisance alarm, fix the float or the wiring.
Do not raise the alarm float to stop it firing. That converts a warning you can act on into a flood you cannot.
Do not reset a thermal alarm repeatedly. Each reset is another heat cycle on the winding.
Do not assume the alarm is wrong because the pump sounds fine. A pump can run, sound normal and deliver nothing — that is exactly the case the high-level alarm exists to catch.
Alarm response procedure for a building
If the station serves a building with staff or tenants, write the response down. The person who hears the alarm is rarely the person who can diagnose it.
| Step | Action |
|---|---|
| 1 | Note the time and which alarm |
| 2 | Look in the tank — is the level high? |
| 3 | If high, stop using the fixtures served by the station |
| 4 | Call the maintenance contact |
| 5 | If the level is normal, log it as a nuisance alarm and report it |
| 6 | Do not silence and leave |
A laminated card next to the control panel with these six lines prevents most of the damage that follows an ignored alarm.
Prevention
| Check | Interval |
|---|---|
| Test the alarm by lifting the float | Monthly |
| Confirm the alarm float sits above the start level | Annually |
| Inspect float bodies for water ingress | Annually |
| Check terminals in the panel and junction box | Annually |
| Test the seal / moisture sensor | Annually |
| Log every alarm with its cause | Ongoing |
The monthly lift test takes a minute and confirms both that the alarm works and that the float is free.
Working on a real project?
Send the fixture list, not the model code
Send the fixture list, required lift height and supply voltage. We will recommend the matching model from the 2026 catalog.
FAQ
What does the alarm on a external lifting station mean? Usually that the water level has reached the alarm float, meaning the pump is not keeping up. Some stations also alarm on motor overload, seal leakage, power failure or run-dry.
Can I just silence it? Only after you have looked in the tank. If the level is normal, it is a nuisance alarm and the float or wiring needs attention. If the level is high, silencing it removes your only warning.
Why does the alarm sound when the tank is nearly empty? The alarm float is stuck up, set too low, fouled on pipework, or the alarm circuit has water in it. Check the float first.
How often should the alarm be tested? Monthly. Lift the float by hand and confirm the alarm sounds, then confirm the pump starts at its own float.
Next step
If the station alarms because the pump cannot keep up, the fix may be a larger unit rather than a repair. Send the model code, the measured inflow and the discharge head, and we will confirm what would actually cope.
Request a quotation · Float switch height · Maintenance schedule
Related reading
- Sewage pump short cycling — the alarm that fires every few minutes
- Sewage pump overheating and cutting out — when the thermal alarm is the one sounding
- Float switch stuck — the nuisance alarm that never clears
Still unsure? Message the engineer on WhatsApp.