A sewage pump that will not start is almost always one of eight faults, and they can be eliminated in a fixed order that takes about twenty minutes with a multimeter. The order matters: start at the supply and work outward toward the motor, because a fault upstream makes every downstream test meaningless. Testing the motor first when the breaker is off wastes an hour and teaches you nothing.

Before anything else: isolate the power and confirm the tank is not full. A full tank on a dead pump is a flood risk, and a full tank makes every subsequent step messy.


The diagnostic order

StepCheckTypical finding
1Supply present at the isolatorNo power — upstream fault
2Breaker or RCD trippedEarth leakage or overload
3Float switch operatingStuck down, snagged or failed
4Control panel outputContactor or relay not pulling in
5Thermal overload trippedReset button popped out
6Capacitor (single phase)Swollen or open circuit
7Motor winding resistanceOpen circuit or short to earth
8Impeller and shaft freeJammed by debris or seized bearing

Cause 1: No supply at the isolator

Start at the point where the station is fed.

Check: voltage at the isolator with the switch closed. On a single-phase unit expect the nominal supply voltage; on three-phase, expect all three phases present and roughly balanced.

Common findings:

  • A local isolator switched off and forgotten after a service.
  • A fused spur with a blown fuse.
  • A shared circuit where something else has taken the supply down.
  • On three-phase, one phase lost — the motor hums but does not start, and will burn out if left.

Fix: restore the supply. If a fuse has blown, find out why before replacing it.


Cause 2: Breaker or RCD tripped

Check: look at the distribution board. A miniature circuit breaker that has tripped sits in the middle position; an RCD has a reset lever.

What the pattern tells you:

  • MCB trips immediately on start: likely a short circuit or a seized motor drawing locked-rotor current.
  • MCB trips after a few minutes: likely overload — a jammed impeller or a pump running beyond its duty.
  • RCD trips: earth leakage. Water in the terminal box, a damaged cable, or a failing winding.

Fix: reset once and observe. If it trips again, do not keep resetting — find the cause. Repeated resetting on an earth fault is how motors get destroyed.


Cause 3: Float switch stuck or failed

This is the most common single cause of "the pump has stopped" on a station that was working yesterday.

Check: lift the float by hand. A working switch clicks audibly and the pump starts. If nothing happens, the switch is either stuck, snagged on the inlet pipe, or electrically open.

Common findings:

  • Float tangled with the inlet pipe or with debris.
  • Float filled with water through a split in the cable sheath, so it no longer floats.
  • Contacts welded closed (pump runs constantly) or open (pump never runs).
  • Float positioned so it cannot rise far enough to trip.

Fix: free the float and test again. If the switch does not click or does not switch, replace it — floats are inexpensive and are not worth repairing. Then reset the start and stop levels so the float has full travel.

For a routine that catches this before it becomes a flood, see our notes on float switch maintenance.


Cause 4: Control panel output

Where the station has a control panel rather than a direct float connection, the fault may sit between the float and the pump.

Check: with the float lifted, listen for the contactor. If the coil does not pull in, the panel is not receiving the signal; if it pulls in but the pump does not run, the fault is downstream.

Common findings:

  • Blown control fuse.
  • Contactor coil open circuit.
  • Burnt contactor contacts from repeated arcing.
  • Loose terminal screw — surprisingly common after a few years of vibration.

Fix: replace the failed component. If contacts are pitted, replace the contactor rather than cleaning it; pitted contacts fail again.


Cause 5: Thermal overload tripped

Most pump control panels include a thermal overload relay with a manual reset.

Check: look for a small button or lever on the overload. If it has popped, the motor ran hot.

Why it ran hot:

  • Pump running beyond its duty point (blocked discharge, wrong selection).
  • Low voltage supply causing high current.
  • Ventilated but enclosed space with no airflow.
  • Repeated short cycling.

Fix: reset it once and monitor. If it trips again within days, the overload is doing its job and the underlying cause needs fixing. Resetting repeatedly without investigating is how a winding fails.


Cause 6: Capacitor failure (single-phase motors)

A single-phase motor uses a start or run capacitor. When it fails, the motor hums without turning.

Check: isolate, discharge the capacitor safely, and test with a multimeter on capacitance range. A swollen or leaking capacitor is failed by inspection alone.

Fix: replace with the same capacitance and voltage rating. A different value will change the starting characteristics.


Cause 7: Motor winding failure

If everything upstream is sound, test the winding.

Check: resistance across the winding terminals and insulation resistance to earth.

ReadingMeaning
Open circuit (infinite resistance)Winding burnt through
Very low resistance with high current drawShort between turns
Low insulation resistance to earthMoisture ingress or insulation breakdown

Fix: a failed winding means a new motor or a new pump. On a compact unit this usually means replacing the unit; on a station with a replaceable pump it means swapping the pump end.

Moisture ingress is the usual root cause, and it usually starts at the cable gland or the seal. Fixing the motor without fixing the seal guarantees a repeat.


Cause 8: Impeller jammed or shaft seized

Check: isolate, then try to turn the impeller through the access port or by removing the pump. It should turn freely by hand.

Common findings:

  • Debris wrapped around the impeller — wipes, hair, string.
  • A hard object lodged between impeller and casing.
  • Seized bearing, usually from long dry running or from a failed seal letting water into the bearing housing.
  • On a cutting impeller, a chipped edge jammed against the cutting plate.

Fix: clear the obstruction. If the shaft will not turn after clearing, the bearing has failed and the pump needs rebuilding or replacing.


When it is not the pump at all

Two situations look like pump failure but are not:

The tank is not filling. If no wastewater is reaching the station, the float never lifts and the pump never runs. Check that the inlet is not blocked and that upstream fixtures are draining.

The float is set too high. A station whose start level is above the normal inflow will appear dead until the tank fills enough — which on a low-flow installation may be days.


Preventing the next failure

The faults above share a pattern: most are caused by debris, moisture or an unserviced float, not by motor failure.

MeasureInterval
Lift and test the float by handMonthly
Check the lid gasket and cable glandEvery service visit
Clear debris from the impellerAnnually, or on any blockage
Test insulation resistanceAnnually
Check the discharge non-return valveAnnually

A maintenance schedule built around these five checks prevents most no-start calls.


Working on a real project?

Send the fixture list, not the model code

Send the fixture list, required lift height and supply voltage. We will recommend the matching model from the 2026 catalog.

FAQ

Why does my sewage pump hum but not start? Usually a failed capacitor on a single-phase motor, a jammed impeller, or a lost phase on a three-phase supply. Isolate, check the impeller turns freely, then test the capacitor.

Can I reset the breaker and keep running? Reset once. If it trips again, stop and find the fault. Repeated resetting on an earth fault or a seized motor will destroy the winding.

The float looks fine but the pump will not run — what next? Test the float electrically rather than visually. A float can look correct and still have open contacts or a water-filled body.

How do I know if the motor is burnt out? Winding resistance open circuit, or very low insulation resistance to earth. Both require a meter; neither can be judged by looking.


Next step

If the pump has failed and the unit is beyond repair, send the model code and the installation details. We will confirm the replacement and whether the existing tank and connections can be reused.

Request a quotation · See the model range · Model code explained


Still unsure? Message the engineer on WhatsApp.

Models referenced in this note