A datasheet is a procurement document, not a brochure. The twelve fields a complete one has, the ones most suppliers leave out, and how to use it in a tender.
A datasheet — sometimes called a technical data sheet, sometimes a technical file — is not a brochure. A brochure persuades; a datasheet specifies. The difference matters because a datasheet is the document you attach to a purchase order, a tender submission or a submittal for approval — and if it is incomplete, you end up accepting whatever arrives.
This article lists the twelve fields a complete datasheet contains, which ones are usually missing, and how to use the document in a procurement process.
It applies equally to a single sewage pump station for a house and to a packaged unit going into a tender for forty.
The twelve fields
| # | Field | Why it is needed |
|---|---|---|
| 1 | Model code and variant | Identifies the exact unit, including voltage and platform |
| 2 | Performance curve | The whole operating range, not one point |
| 3 | Duty point | Flow and head at the intended operating condition |
| 4 | Shut-off head | The maximum lift the pump can achieve |
| 5 | Free passage | The largest solid that passes — the blockage predictor |
| 6 | Impeller type and material | Determines what the pump handles and how long it lasts |
| 7 | Tank volume and working volume | Sizing and cycle behaviour |
| 8 | Motor data | Power, voltage, frequency, current, speed, insulation class, protection rating |
| 9 | Connection sizes | Inlet, discharge, vent — with thread or flange standard |
| 10 | Maximum liquid temperature and pH range | Duty limits that are easy to exceed |
| 11 | Weight and dimensions | Freight, handling and installation planning |
| 12 | Standards and conformity | Which standard the unit is made to, and the declaration of conformity |
A sewage lifting station datasheet missing any of these is a document that will cost you time later — usually at the point where you cannot answer a customer's or an inspector's question.
The three fields most often missing
Free passage
Many datasheets quote the discharge port size and leave you to assume the free passage is the same. It is not — the governing restriction is usually the gap between the impeller and the volute, which is smaller.
Ask explicitly: what is the free passage, and where is it measured? A unit with a 50 mm discharge and a 20 mm impeller clearance has a free passage of 20 mm.
Working volume
Tank volume is the headline number. Working volume — the volume between start and stop levels — is the number that determines cycle frequency.
A 90 litre tank with 20 litres of working volume cycles four times more often than a 90 litre tank with 80 litres of working volume. Same tank, very different life.
Duty rating
Whether the pump is rated for continuous or intermittent running, and at what ambient and liquid temperature. A unit rated for intermittent domestic use will not survive a commercial kitchen's operating hours, even if the flow figures match.
Reading the curve section
The curve is the most important part of the datasheet and the part most often skipped.
| Element | What to look for |
|---|---|
| Horizontal axis | Flow, in m³/h or l/min — check which |
| Vertical axis | Head, in metres |
| The curve itself | Should fall from shut-off head to maximum flow |
| The duty point | Should be marked, or you should be able to plot yours |
| Efficiency or power curves | Optional, but useful for energy comparison |
| The stated speed | A curve at 2900 rpm is not valid at 1450 rpm |
The test: plot your required duty point on the curve. If it sits well to the left of the best-efficiency area, the pump is oversized. Well to the right, and it is undersized and will run hot. Either way, the datasheet has told you something a brochure never would.
Full method: how to read a pump performance curve.
Using a datasheet in a tender
If you are specifying for a project, the datasheet is what you attach to the specification so that every bidder quotes the same thing.
| Step | Action |
|---|---|
| 1 | Write the duty requirement: flow, head, free passage, tank working volume |
| 2 | Ask each bidder for a datasheet covering the twelve fields |
| 3 | Reject any submission missing fields 2, 5 or 7 — those three decide whether the unit works |
| 4 | Compare the curves at your duty point, not at their headline point |
| 5 | Require the declaration of conformity as a separate document |
A sewage lifting station specification written this way is short — half a page — and it removes most of the ambiguity that makes tender evaluation slow.
Datasheet versus catalogue
These get confused, and the confusion causes problems.
| Document | Purpose | Content |
|---|---|---|
| Datasheet | One model, all technical fields | Curves, dimensions, materials, limits |
| Catalogue | The whole range, for selection | Summary tables, model codes, headline figures |
| Technical file | The full documentation set | Datasheets, manuals, declarations, test references |
| Specification | What you require | Written by the buyer, not the supplier |
When you ask for a sewage lifting station catalog, you get a selection tool. When you ask for a datasheet, you get a procurement document. Ask for both, and know which one you are holding.
What a complete datasheet lets you do
| Task | Requires |
|---|---|
| Confirm the unit suits the duty | Curve + duty point |
| Predict blockage risk | Free passage + impeller type |
| Predict cycle frequency | Working volume + start/stop levels |
| Plan the electrical supply | Motor data + current |
| Plan the pipework | Connection sizes and standards |
| Plan freight | Weight and dimensions |
| Answer a building inspector | Standards + declaration of conformity |
| Order a spare part | Model code + variant + parts list |
If the datasheet cannot support all eight, it is incomplete.
Red flags in a datasheet
| Red flag | What it suggests |
|---|---|
| Curve with no axis units | The figures are illustrative |
| One flow figure, no head | No tested data |
| "Free passage: large" | Not measured |
| Tank volume but no working volume | Working volume is small |
| No speed stated on the curve | The curve may be from a different variant |
| Different power ratings in different documents | No document control |
| No declaration of conformity | Compliance is a claim, not a document |
A ready-to-install sewage lifting unit with a complete datasheet is easier to approve, easier to install and easier to support than one with a brochure — and the difference is visible before you order.
Working on a real project?
Send the fixture list, not the model code
Send the fixture list, required lift height and supply voltage. We will recommend the matching model from the 2026 catalog.
FAQ
What should a sewage pump datasheet include? Twelve fields: model and variant, performance curve, duty point, shut-off head, free passage, impeller type and material, tank and working volume, motor data, connection sizes, temperature and pH limits, weight and dimensions, and standards with the declaration of conformity.
What is the difference between tank volume and working volume? Tank volume is the physical size of the tank. Working volume is the volume between the pump's start and stop levels — the water actually moved each cycle. Working volume determines cycle frequency.
Why does free passage matter more than flow rate? Because it predicts whether the pump will block. A pump with a good flow rate and a small free passage is a pump that will need clearing, regardless of how much water it can move.
Can I compare two pumps from their datasheets alone? Yes, if both datasheets are complete. Compare the curves at your duty point, then free passage, then working volume. Those three decide most of the outcome.
Next step
Tell us the duty point and the platform you need, and we will send the datasheet with the curve, free passage, working volume, motor data and declaration of conformity for the units that fit — in a form you can attach to a tender.
Request a quotation · Read a pump curve · See the range
Related reading
- How to compare sewage lifting stations across brands — what to do with the datasheets once you have them
- How to read a pump performance curve — the field most often missing from a datasheet
- What is free passage in a sewage pump — the number buyers misread most often
- CE marking for sewage lifting devices — the declaration that belongs with the datasheet
- Selection checklist for contractors — the measurements you need before requesting one
- IP ratings for sewage pumps — reading the protection digit properly
Still unsure? Message the engineer on WhatsApp.
Read more
- Read more:Floor-Mounted vs Buried Sewage Stations
- Read more:What Is Free Passage in a Sewage Pump?
- Read more:How Long Does a Sewage Pump Last?