Head against flow, the duty point, efficiency and power — what each part of the curve tells you, and the three readings that cause most selection errors.
A pump performance curve plots head on the vertical axis against flow on the horizontal axis. The curve slopes downward from left to right: at zero flow the pump produces its maximum head, and as flow increases the head it can produce falls, reaching zero at maximum flow. Your installation has its own curve, sloping the other way, and where the two intersect is the duty point — the flow and head at which the pump will actually operate.
That intersection, not the headline numbers on the datasheet, is what the pump will do in your building.
The axes
Vertical — head. The height the pump can lift to, in metres. It is not pressure, though the two are related; a metre of head corresponds to a fixed pressure for a given liquid density.
Horizontal — flow. The volume moved per unit time, in m³/h or L/min.
Both are needed. A single figure for either is meaningless without the other.
The four features of every curve
1. Shut-off head — where the curve meets the vertical axis, at zero flow. This is the highest point the pump can lift to with nothing moving. It is the figure most often quoted and the least useful on its own, because at zero flow the pump is doing no work.
2. Maximum flow — where the curve meets the horizontal axis, at zero head. The most the pump will move with no resistance at all. Also of limited practical use, because every real installation has resistance.
3. The shape between them — the useful part. Some curves are flat across a wide flow range; others fall steeply. A flat curve gives stable flow as head varies; a steep curve gives flow that changes sharply with small changes in head.
4. The efficiency curve, usually plotted on the same chart against a second vertical axis. It rises to a peak and falls away on both sides.
The duty point
Your installation has a system curve: as flow increases, the head required to push it through the pipe rises, because friction rises with the square of flow. Plot that on the same axes and it slopes upward from left to right.
Where the pump curve and the system curve cross is the duty point. That is where the pump will settle, because it is the only point where the head the pump produces equals the head the system requires.
The selection question is not "what is this pump's maximum head" but "where does the duty point fall on this curve".
Three misreadings that cause bad selections
Misreading 1: choosing on shut-off head.
A pump whose maximum head equals your calculated total dynamic head will deliver almost no flow, because the duty point would be at the far left of the curve where flow approaches zero. You need head at your flow, not head at zero flow.
Misreading 2: choosing on maximum flow.
Symmetrically, the maximum flow figure occurs at zero head — a condition that does not exist in a real installation. A pump rated at 200 L/min may deliver 90 L/min at your actual head.
Misreading 3: ignoring where the duty point sits.
A duty point near the right-hand end of the curve is unstable: a small increase in head — from pipe fouling, a partly closed valve — produces a large drop in flow. A duty point in the middle third of the curve behaves predictably across the service life.
A worked comparison
Two units in the same range, using published figures:
| AT-C300A | AT-C450A | |
|---|---|---|
| Rated power | 300 W | 450 W |
| Maximum head | 6.5 m | 8 m |
| Maximum flow | 100 L/min | 125 L/min |
For a duty requiring 3.7 m of head and a modest domestic flow, both are comfortably capable. The 300 W unit has 2.8 m of head in reserve above the requirement; the 450 W unit has 4.3 m.
That margin is not wasted — it covers pipe fouling over the service life — but it also means the 450 W unit is operating further to the left on its curve at this duty, which is the less efficient region. For a single bathroom with a short route, the smaller unit is the better match. For a longer route or a larger fixture group, the head requirement rises and the larger unit earns its place.
The curves for each model are on its product page, for example AT-C300A and AT-C450A.
What else the curve tells you
Current draw. The power curve rises toward the right. A duty point at the far right means the motor is drawing near its maximum, leaving no margin for fouling.
Noise and vibration. Operating far from the best efficiency point increases hydraulic noise and shaft loading.
Wear. A pump run consistently at the extremes of its curve wears faster than one run near its design point.
Stability in a varying system. On a flat curve, flow barely changes as the system resistance changes. On a steep curve, the same change in resistance produces a large change in flow. For a station where the discharge route fouls over time, a flatter curve is more forgiving.
How to use a curve in selection
- Calculate total dynamic head at your design flow — static lift plus friction, as set out in how to calculate total dynamic head.
- Estimate design flow from the fixture group.
- Plot the point (flow, head) on the candidate curves.
- Check it sits in the middle band of the curve, not at either extreme.
- Confirm the efficiency at that point is reasonable.
- Check the current draw leaves margin.
- Allow 10–15% head margin for fouling.
If the duty point falls outside the curve entirely — above it — the pump cannot do the job. If it falls at the far right, the pump can do it today but will be marginal in a few years.
Working on a real project?
Send the fixture list, not the model code
Send the fixture list, required lift height and supply voltage. We will recommend the matching model from the 2026 catalog.
FAQ
What is a pump curve? A graph of head against flow for a specific pump. It shows what head the pump can produce at each flow rate.
What is the duty point? The intersection of the pump curve and the system curve — the flow and head at which the pump will actually operate in a given installation.
Why is maximum head not a useful selection figure? Because it occurs at zero flow, where the pump moves no water. What matters is the head available at your design flow.
Do I need the curve or just the datasheet figures? The datasheet figures are the endpoints of the curve. The curve tells you what happens between them, which is where your duty point will be.
Next step
Send the calculated head and design flow, and we will identify the model whose curve covers that duty point with sensible margin, and send the curve for that unit.