Two digits, two different kinds of protection. Why a submersible sewage pump needs an immersion rating, and why IP68 on its own does not mean "permanently waterproof".
An IP rating has two digits and they answer two separate questions: how well is the enclosure sealed against solid objects, and how well against water. Most specification mistakes come from reading only the second digit.
For a sewage pump the rating matters because the pump sits in the medium it is pumping. Getting the rating wrong does not show up as a fault on day one — it shows up as a motor that fails a year early, with water in the winding.
What the two digits mean
The rating comes from IEC 60529, which is an international standard and applies regardless of who made the pump.
| Position | Protects against | Scale |
|---|---|---|
| First digit | Solid objects, including dust | 0–6 |
| Second digit | Water | 0–8 (and 9K for high-pressure jet) |
The digits are independent. IP54 and IP68 differ in both, and comparing only the water digit tells you half the story.
First digit: solids
| Digit | Protection |
|---|---|
| 4 | Objects over 1 mm — tools, wires, screws |
| 5 | Dust protected — dust may enter but not in quantity to interfere |
| 6 | Dust tight — no dust ingress |
For a sewage pump, the first digit matters less than the second in normal service — but it matters a lot during storage and installation, when grit and debris are around.
Second digit: water
| Digit | Protection |
|---|---|
| 4 | Splashing water from any direction |
| 5 | Water jets from any direction (6.3 mm nozzle) |
| 6 | Powerful water jets (12.5 mm nozzle) |
| 7 | Temporary immersion — 1 m for 30 minutes, defined conditions |
| 8 | Continuous immersion — depth and duration agreed between manufacturer and user |
The critical distinction for a sewage pump is between 7 and 8. A submersible pump that sits in a tank is continuously immersed, so it needs an 8 — a 7 is not enough.
What each rating means for a sewage pump
| Rating | Where it fits | Suitable for a submersible sewage pump? |
|---|---|---|
| IP54 | Motor in a dry chamber, splashing possible | No — dry-installed only |
| IP55 | Motor in a dry chamber, wash-down possible | No — dry-installed only |
| IP65 | Dust tight, water jets | No — dry-installed, wash-down |
| IP67 | Dust tight, temporary immersion | No — not for continuous immersion |
| IP68 | Dust tight, continuous immersion | Yes — the normal rating for a submersible pump |
A dry-installed pump sits in a dry chamber beside the wet well, so IP54 or IP55 is normal and correct. A submersible pump sits in the wastewater, so it needs IP68.
If a pump sold as submersible carries only IP67, ask why. It may be intended for occasional immersion rather than continuous service, which is a different product.
IP68 is not a single specification
This is the part that catches buyers out. IP68 does not define a depth. The standard says the conditions are agreed between manufacturer and user — so one manufacturer's IP68 may be 1 m for 24 hours and another's may be 10 m permanently.
| What to ask | Why |
|---|---|
| To what depth is the IP68 rating stated? | The number is meaningless without it |
| For how long? | Continuous, or a stated duration |
| Is the cable entry included in the rating? | A sealed motor with an unsealed gland is not IP68 |
| What is the sealing arrangement? | Double mechanical seal, lip seal, or both |
The cable entry point is the most common weak link. A motor housing rated IP68 with a cable gland that is not is only as good as the gland.
In practice: a submersible sewage pump installed in a tank is immersed to a depth of well under a metre, continuously. Almost any honestly stated IP68 covers that. The rating matters most when the pump is in a deep wet well or a flooded chamber.
The installation details that defeat a good rating
A pump can be correctly rated and still fail from water ingress, because the rating applies to the enclosure as supplied, not to the installation.
| Detail | What goes wrong |
|---|---|
| Cable gland not tightened to torque | Water tracks along the cable |
| Cable damaged during installation | Sheath nicked on a sharp edge or a guide rail |
| Cable joint below water level | A joint is not IP68 unless it is made for it |
| Pump run dry | Overheating damages the seal faces, then water enters |
| Seal worn, not replaced | The rating protects the motor, not a worn seal |
| Pump left partially submerged | Cooling fails before sealing does |
The cable is the most common path for water. It is also the part most often handled carelessly on site — pulled through a tight duct, bent sharply at the gland, or left with a loop that collects water.
Dry-installed pumps: the rating is different, and that is correct
A dry-installed pump does not need IP68 and should not be specified with it. It sits in a dry chamber, and the requirement is protection against splashes and wash-down, not immersion.
| Arrangement | Typical rating | Reason |
|---|---|---|
| Submersible in a tank | IP68 | Continuously immersed |
| Dry-installed, dry chamber | IP54 or IP55 | Splash and wash-down only |
| Dry-installed, chamber may flood | IP68, or a flood-tolerant design | The chamber can fill if the sump pump fails |
The third row is worth thinking about. A dry chamber is dry until something goes wrong — a leaking seal, a failed chamber drain pump, a rising water table. If the chamber can flood, the pump needs to survive being flooded, which is a different requirement from normal service.
What to put in a specification
| Requirement | Wording that works |
|---|---|
| Submersible pump | "IP68, continuous immersion, rated depth stated" |
| Dry-installed pump | "IP55 minimum, suitable for wash-down" |
| Cable entry | "Cable entry sealed to the same rating as the enclosure" |
| Seal arrangement | "Double mechanical seal, oil chamber monitored" |
| Dry chamber that can flood | "Pump suitable for occasional immersion, or chamber drained by independent pump" |
Working on a real project?
Send the fixture list, not the model code
Send the fixture list, required lift height and supply voltage. We will recommend the matching model from the 2026 catalog.
FAQ
Is IP68 waterproof? It means protected against continuous immersion under conditions agreed with the manufacturer. It does not mean indestructible, and it does not specify a depth on its own. Ask for the rated depth.
Can I use an IP55 pump in a sewage tank? No. IP55 is protection against water jets, not immersion. A pump sitting in wastewater needs an immersion rating.
Is a higher IP rating always better? Not automatically. A higher rating usually means more sealing, which can mean more heat retained and a more expensive pump. Match the rating to the arrangement — IP68 for submersible, IP55 for dry-installed.
My pump is IP68 but the motor filled with water. Why? Almost always the cable entry, a damaged cable, or a worn shaft seal. The rating covers the enclosure as supplied; it does not cover a gland that was not tightened or a seal at the end of its life.
Next step
Tell us the arrangement — submersible in a tank, or dry-installed in a chamber — and the depth involved, and we will confirm the protection rating and sealing arrangement the installation needs, with the rated depth stated rather than implied.
Request a quotation · Submersible vs dry-installed · See the range
Related reading
- Submersible vs dry-installed lifting stations — the arrangement that decides the rating
- Sewage pump datasheet: what a complete one contains — where the rating belongs
- Sewage pump overheating and cutting out — the failure a dry run causes
- Flood-proofing a sewage lifting station — when the dry chamber floods
- How to compare stations across brands — reading claims critically
Still unsure? Message the engineer on WhatsApp.