Non-Return Valve and Isolation Valve: Both?

2026-11-056 min readInstallation and Commissioning

One prevents backflow, the other lets you service the pump. They are not interchangeable, and fitting only one creates a problem that appears later.

They are two different devices with two different jobs, and both belong on a lifting station discharge.

The non-return valve opens in one direction only. Its job is to stop water flowing back from the rising main into the chamber when the pump stops. It operates automatically and has no handle.

The isolation valve — a gate valve, a ball valve or a butterfly valve — is manual. Its job is to let you close the discharge so the pump or the non-return valve can be worked on without draining the rising main.

The confusion arises because both sit on the same short length of pipe and both are "a valve". But one is a check device and the other is a service device, and using either for the other's job produces a specific, predictable failure.


What happens with only a non-return valve

This is the common installation: pump, non-return valve, straight into the rising main. It works, and it is unserviceable.

Two consequences:

You cannot remove the pump without dealing with the water above it. Every service means draining the rising main, or accepting a wet job. On a station where the discharge rises several metres, that is a significant volume.

You cannot maintain the non-return valve itself. The non-return valve is a wear item. Its seat collects debris, its flap or ball can jam, and it eventually fails to seal. To inspect it you need to isolate the pipe above it — and there is nothing to isolate it with.

The second point is the one people discover the hard way. A non-return valve that has stopped sealing causes the pump to short-cycle, and the fix requires access to the valve. Without an isolation valve, that access means draining down.


What happens with only an isolation valve

Less common, and worse.

The water flows back on every stop. With no non-return valve, the column of water in the rising main falls back into the chamber as soon as the pump stops. The chamber refills partially, the level rises, the pump restarts, and the cycle repeats.

The result is short cycling, which is the fault that damages a pump fastest: repeated starts, capacitor stress, heat, and a seal running in disturbed water. See Sewage pump short cycling.

There is a second consequence: the pump restarts against a falling column of water rather than a static one, which is a less stable hydraulic condition and can produce vibration.


The correct arrangement

The standard order, from the pump outwards:

PositionComponentPurpose
1Pump—
2Non-return valveStops backflow
3Isolation valveLets you service everything upstream
4Rising main to the sewer—

Two rules that follow from this order:

The non-return valve goes on the pump side of the isolation valve. If it is the other way round, closing the isolation valve leaves the non-return valve under pressure from the main, and you still cannot service it.

The isolation valve goes where a person can reach it. This sounds obvious and is routinely ignored. A valve buried under a floor plate or behind the chamber wall is a valve that will be left open.

On a buried lifting station where the discharge leaves through a wall at high level, the practical arrangement is often a compact pump connection unit that incorporates both, with the isolation handle accessible at floor level.


The third component people forget

Between the pump and the non-return valve there is usually a flexible connection. It is not a valve and it is not optional on a rigid discharge: it breaks the transmission of pump vibration into the pipework.

Without it, the pump's vibration loads the non-return valve body, the isolation valve and every joint in the run. The consequence is a valve that leaks at its stem or a joint that weeps — and the cause is upstream of both. This is covered in Sewage pump vibration.

So the full assembly is: pump — flexible connection — non-return valve — isolation valve — rising main. Four components, and each one has a distinct job.


Vertical discharge: a separate question

On a vertical rising main the non-return valve choice changes. A standard swing-check valve relies on gravity to close, and on a vertical pipe the flow direction and the closing direction do not align the way they do horizontally.

The options are a spring-loaded check valve, a ball check valve, or a lift check — and the choice depends on the orientation and the flow velocity. This is covered in How to fit a non-return valve on a vertical discharge, and the placement question in Where to fit the non-return valve.

The isolation valve does not change: it is still needed, still downstream, still manual.


Sizing the valves

Two sizing points that cause trouble:

Do not reduce the bore. A valve with a smaller bore than the pipe adds friction loss at exactly the point where the pump is working hardest. On a long or high-head discharge, this shows up as reduced flow that nobody attributes to the valve.

Match the pressure rating to the static head. The valve downstream of the pump sees the full static head of the rising main when the pump stops, plus any surge. A valve rated below that is a valve that will leak or fail.


Servicing: what the arrangement buys you

With both valves fitted, a service becomes straightforward:

  1. Close the isolation valve.
  2. Release pressure between the isolation valve and the pump — there should be a drain point for this.
  3. Lift the pump, or open the non-return valve for inspection.
  4. Reassemble, open the isolation valve, run and check.

Without the isolation valve, step 1 does not exist, and the whole procedure becomes a draining operation. On a domestic station that is an inconvenience; on a commercial one it is a shutdown.

A drain point between the two valves is worth mentioning because it is small, cheap, and constantly omitted. Without it, step 2 is done by loosening a connection and catching what comes out. On a sewage lifting unit fitted into an existing building, where the pipe run was never designed for servicing, that small fitting is often the difference between a planned visit and a wet one.


Working on a real project?

Send the fixture list, not the model code

Send the fixture list, required lift height and supply voltage. We will recommend the matching model from the 2026 catalog.

FAQ

Can a non-return valve be used to isolate the pump? No. It closes in one direction only, it is not designed to hold pressure reliably, and it has no means of being locked closed. It will pass water, and it will do so while someone is working on the pump.

Is a gate valve or a ball valve better? A ball valve gives a quarter-turn and a clear visual indication; a gate valve gives a slower operation and less turbulence when fully open. Both are used. What matters more is that it is accessible and that its bore is not reduced.

Do I need a non-return valve if the discharge goes straight up and over? Yes. The static head still pushes water back when the pump stops, whatever the route.

Where should the drain point go? Between the isolation valve and the pump, so the section that has to be opened can be emptied. It is a small fitting and it saves a wet service.


Next step

Tell us the discharge route, the static head and how the pump is accessed for service — and we will confirm the valve arrangement and where each component needs to sit to be both correct and reachable.