How Much Head a Sewage Pump Loses per Metre of Pipe

2026-11-055 min readSelection Guide

Friction loss per metre depends on bore, material and flow — and rises with the square of velocity. Indicative figures and why a small bore costs more than it looks.

A sewage pump loses head to friction in every metre of pipe it pushes through, and the amount depends on three things: the internal bore, the roughness of the pipe, and the flow rate. As a rough order of magnitude for small-bore drainage at domestic flows, friction loss runs from around 0.02 m per metre in a 50 mm pipe up to 0.15 m per metre or more in a 32 mm pipe at the same flow. Halve the diameter and the loss does not double — it rises far more steeply than that.

This is why a long, small-bore discharge route can consume more head than the vertical lift it is supposed to achieve.


Why friction rises so sharply

Friction loss is driven by velocity, and velocity depends on flow divided by cross-sectional area. For a given flow:

velocity ∝ 1 / diameter²

Halve the bore and the velocity quadruples. Friction loss rises roughly with the square of velocity, so the same flow through half the diameter produces something in the region of sixteen times the loss per metre.

That relationship is the single most important thing to understand about discharge pipework. It is why reducing a pipe to make a route easier is almost never a neutral decision.


Indicative friction loss figures

The table below gives order-of-magnitude values for smooth plastic pipe carrying wastewater, to show the scale rather than to replace a proper table. Use the manufacturer's or the code's figures for an actual calculation.

BoreAt low domestic flowAt moderate flowAt high flow
32 mm≈ 0.04 m/m≈ 0.12 m/m≈ 0.25 m/m and above
40 mm≈ 0.02 m/m≈ 0.05 m/m≈ 0.12 m/m
50 mm≈ 0.01 m/m≈ 0.02 m/m≈ 0.05 m/m
63 mm≈ 0.004 m/m≈ 0.01 m/m≈ 0.02 m/m

Read the table as a ratio rather than as values. The important pattern is the difference between columns and rows: flow matters, but bore matters more.


What this does to a real installation

Take a basement bathroom needing 2.5 m of vertical lift, with the stack on the far side of the building.

Case 1 — 50 mm pipe, 6 m horizontal, 4 elbows: Friction at the design flow is a few tenths of a metre. Total head ≈ 2.9 m.

Case 2 — 32 mm pipe, same route: Friction at the same flow is several times higher. Total head may reach 4.5–5 m.

Same building, same fixtures, same vertical lift — and the smaller pipe has nearly doubled the head requirement. If the unit was selected on the 2.5 m vertical figure, it is now operating well beyond its intended duty point.

This is the arithmetic behind most "the pump is too small" complaints. The pump was not too small; the pipe was.


Fittings count as pipe

Every bend, valve and transition adds resistance. Rather than calculating each one, convert to an equivalent length of straight pipe and add it to the run.

FittingApproximate equivalent length
90° elbow0.5–1.5 m
45° elbow0.3–0.8 m
Long-radius bend0.3–0.6 m
Non-return valve1.5–3 m
Gate valve (open)0.2–0.5 m

Four elbows and a non-return valve can add more equivalent length than ten metres of straight pipe. On a basement discharge that snakes around a corner and up a wall, this is frequently the largest single component of the friction calculation.

The full method, with a worked example, is in how to calculate total dynamic head.


Material matters, but less than you think

Pipe roughness affects friction, and different materials have different roughness values. In small-bore domestic drainage the difference between smooth plastic and older rougher materials is real but secondary to the effect of bore and flow.

What matters more over time is fouling. A pipe that starts smooth accumulates scale, grease and biofilm on its internal surface, and the effective roughness rises. A discharge line that was adequately sized when new may be marginal after several years.

That is the argument for a modest head margin — around 10–15% — in the original selection.


The velocity trade-off

There is a lower limit to velocity as well as an upper one.

Too slow: solids settle. Wastewater needs a minimum velocity to stay self-cleansing, typically around 0.7–1.0 m/s in a discharge line. A pipe that is oversized for the flow drops below that threshold and silts up over months.

Too fast: friction loss rises steeply, noise increases, and the pipe wears at bends.

The design aim is a bore that keeps velocity in the self-cleansing band at the design flow, without pushing friction loss beyond what the pump can deliver. That is a narrower target than it sounds, and it is why discharge bore and pump selection have to be decided together — see how to choose discharge pipe diameter.


Practical rules

  1. Never reduce the bore to make the route easier. The reduction becomes the governing restriction and the blockage point.
  2. Count the bends. They are usually the largest hidden component.
  3. Measure the horizontal run, not just the vertical lift.
  4. Calculate at the design flow, not at the pump's maximum.
  5. Allow a modest margin for fouling over the service life.
  6. Check the resulting velocity sits in the self-cleansing band.

Working on a real project?

Send the fixture list, not the model code

Send the fixture list, required lift height and supply voltage. We will recommend the matching model from the 2026 catalog.

FAQ

How much head does a sewage pump lose per metre of pipe? It depends on bore, material and flow. As a rough guide, a 50 mm pipe at domestic flows loses a few hundredths of a metre per metre, while a 32 mm pipe at the same flow loses several times more.

Does horizontal pipe count toward head? Yes, as friction head. It does not add static head, but on a long horizontal run the friction can exceed the vertical lift.

Why does a smaller pipe lose so much more head? Because velocity rises with the inverse square of diameter. Halving the bore quadruples the velocity, and friction rises roughly with the square of velocity.

Can I use a larger pipe to reduce head loss? Yes, up to a point. But an oversized pipe drops below the self-cleansing velocity and solids settle. The aim is a bore that keeps the flow moving, not the largest pipe that fits.


Next step

Send the discharge route — bore, length, bend count and the height to the sewer connection — and the fixture list. We will calculate the head and confirm the model and the connection set.

Request a quotation · Calculate total dynamic head · See the range


Still unsure? Message the engineer on WhatsApp.