Total dynamic head is static lift plus friction loss plus discharge pressure. Here is the calculation, a worked example, and the four mistakes that undersize stations.
Total dynamic head (TDH) is the sum of three things: the static lift from the pump's start level to the highest point of the discharge route, the friction loss through the pipe and fittings at the actual flow rate, and any residual pressure required at the discharge point. It is expressed in metres of head, not in bar or in floor height. Getting this number right is the difference between a station that empties the tank in a minute and one that runs for ten and eventually overheats.
Most undersized installations are not undersized on flow. They are undersized on head, because somebody measured the ceiling height instead of the pipe route.
The formula
TDH = static head + friction head + discharge pressure head
Three components, each with its own trap.
Static head
Static head is the vertical distance the water must be lifted, measured from the pump start level — not the floor — to the highest point of the discharge route.
Two details matter here:
- Measure from the start level, not the tank bottom. The pump begins lifting when the water reaches the float's start position. Using the tank floor adds a height that is never actually pumped.
- Measure to the highest point, not the outlet. If the discharge rises to a soil stack connection at first-floor level and then runs horizontally, the lift is to that high point. A horizontal run at the top of the lift does not reduce the static head.
Friction head
Friction head is the pressure lost to resistance as water moves through the pipe, bends, valves and fittings. It rises with the square of the flow, which is why it is small at low flow and dominant at high flow.
You need three inputs:
- Flow rate — the duty flow you are designing for, in m³/h or L/min.
- Pipe internal diameter and material — friction loss tables are per metre of pipe at a given flow.
- Fitting count — every bend, valve and transition adds resistance, usually expressed as an equivalent length of straight pipe.
Discharge pressure head
Usually zero for a gravity-connected discharge. It becomes relevant when the station discharges into a pressurised line, a raised fitting or a manifold. If the discharge is open to a gravity drain, this term drops out.
Equivalent lengths for fittings
Rather than calculating each fitting individually, most engineers convert fittings to an equivalent length of straight pipe and add it to the run. Indicative values for common fittings in small-bore drainage:
| Fitting | Approximate equivalent length |
|---|---|
| 90° elbow | 0.5–1.5 m of straight pipe |
| 45° elbow | 0.3–0.8 m |
| Sweep bend (long radius) | 0.3–0.6 m |
| Non-return valve (swing) | 1.5–3 m |
| Gate valve (open) | 0.2–0.5 m |
| Sudden contraction or expansion | 0.3–1 m |
These are approximations — the exact figure depends on diameter, material and flow. For a small domestic installation they are accurate enough; for a large station, use the manufacturer's tables.
The point of the table is not precision. It is to show that four elbows and a non-return valve can add more friction than ten metres of pipe, which is the thing most site measurements miss.
Worked example
A basement drainage. The station sits on the floor, and the discharge rises to a soil stack connection 2.6 m above the tank's start level, then runs 6 m horizontally to the stack.
| Item | Value |
|---|---|
| Static lift (start level to stack connection) | 2.6 m |
| Horizontal run | 6 m |
| Fittings: 4 × 90° elbows, 1 non-return valve, 1 gate valve | ≈ 4 × 1.0 + 2.0 + 0.3 = 6.3 m equivalent |
| Total effective pipe length | 6 + 6.3 = 12.3 m |
| Friction loss at design flow (from table, small bore) | ≈ 0.09 m per metre |
| Friction head | 12.3 × 0.09 ≈ 1.1 m |
| Discharge pressure head | 0 (gravity connection) |
| Total dynamic head | 2.6 + 1.1 = 3.7 m |
Note what happened: the static lift is 2.6 m, but the station must actually deliver 3.7 m. If the unit was chosen on the 2.6 m figure alone, it will operate further out on its curve than intended — more flow than needed initially, then progressively less as the impeller and pipe foul.
Add a long horizontal run, a few more bends, or a smaller discharge bore and the friction term grows quickly. On a 20 m run with eight elbows, friction can easily exceed the static lift.
The four mistakes that undersize a station
1. Measuring floor to ceiling instead of start level to high point.
Gives a static head that is either too high (if measured from the tank floor) or too low (if the high point is above the ceiling line). Neither is right.
2. Ignoring the horizontal run.
Horizontal pipe has friction but no static lift. Installers frequently count only the vertical rise. On a basement where the stack is on the far side of the building, the horizontal run can be the largest single component of TDH.
3. Counting bends as nothing.
Six elbows in a small-bore discharge can add the equivalent of several metres of pipe. This is where "it worked on the last job" installations fail — the last job had a straighter route.
4. Calculating at the wrong flow.
Friction head depends on flow, and flow depends on which point of the curve the pump settles at. If you calculate friction at the pump's maximum flow but the system settles at a lower flow, you have overestimated; if you use the nominal rated flow and the system runs higher, you have underestimated. For most small installations, calculating at the design duty flow and then confirming the resulting duty point on the pump curve is close enough.
From TDH to a model choice
Once you have the TDH, the selection is straightforward: find the point on the pump curve where the required flow meets the calculated head, and check that the resulting operating point sits comfortably inside the curve rather than at the far right-hand end.
Two checks before you commit:
- Is the duty point on the flat or the steep part of the curve? A duty point on the steep section means small changes in head produce large changes in flow — the station will behave inconsistently as the pipe fouls.
- Is there margin? A small allowance — around 10–15% on head — covers pipe fouling over the service life without pushing the pump into an inefficient region.
If the calculation puts you near the top of a compact unit's curve, that is the signal to move up a model or consider an external station rather than accept a marginal selection. Our European Type and American Type ranges publish power, flow and head per model so the duty point can be checked against the actual curve, and the AT-S external station range covers 25 L to 460 L where the building discharge exceeds what a compact tank can buffer.
Working on a real project?
Send the fixture list, not the model code
Send the fixture list, required lift height and supply voltage. We will recommend the matching model from the 2026 catalog.
FAQ
Is total dynamic head the same as maximum head? No. Maximum head is the shut-off head on the pump curve at zero flow — the highest point the pump can lift to with no water moving. Total dynamic head is what the system requires at the design flow. A pump whose maximum head equals your TDH will deliver almost no flow.
Does horizontal pipe count toward static head? No. Horizontal runs contribute friction head, not static head. But they still count toward the total, and on long runs they can dominate it.
How much margin should I allow? Around 10–15% on head is a common allowance for pipe and impeller fouling over the service life. More than that usually means the model is oversized for the duty.
What if I do not know the flow? Estimate it from the fixture group — the number and type of outlets discharging into the station. Our sizing guide sets out the fixture-based approach.
Next step
Send the measured lift, the pipe route with fitting count, the discharge bore and the fixture list. We will calculate the duty point and confirm the model, with the parameter table for that unit.
Request a quotation · See the model range