A wholesaler's guide to blackwater vs greywater pumps: EN 12050 classes, cutter vs vortex designs, and how to match Anteloy AT and AT-S models to each job.
Blackwater and greywater pumps are not interchangeable, and mixing them up causes callback complaints in basement drainage. Blackwater carries toilet solids and long fibres that need a macerating cutter or a generous free passage; greywater is free of faecal matter but carries grease, hair and detergent residue. The right pump follows from the fixtures served and the fluid class. This guide gives wholesalers, distributors and contractors a practical framework, using Anteloy AT macerators and AT-S lifting stations as reference.
Blackwater and greywater are different fluids
In drainage engineering, basement wastewater is separated by source and contaminant load. Blackwater is heavily contaminated toilet effluent: faecal matter and paper, long fibres and organic solids. If it enters a small-bore pipe without first being macerated or passed through a large opening, solids build up and the line blocks. A blackwater pump must therefore cut the solids down to size or pass them through a wide free passage.
Greywater, or effluent, comes from showers, washbasins, baths, washing machines and kitchen sinks. It contains no faecal solids, but it is far from clean: grease, hair, textile fibres and detergent residue are common, and discharge temperature can swing sharply. Greywater equipment is designed to tolerate those swings and resist grease build-up inside the chamber.
The split follows the fixtures: add a toilet and the duty becomes blackwater, changing both the mechanism and the model.
What the EN 12050 classes describe
EN 12050 is the European framework for lifting equipment for faecal and non-faecal wastewater. The parts most often quoted in selection are:
- EN 12050-1 — equipment for wastewater containing faecal matter (blackwater).
- EN 12050-2 — equipment for wastewater without faecal matter (greywater / effluent).
- EN 12050-3 — equipment for limited applications that also contains faecal matter, such as a single WC where a full lifting station is not appropriate.
These parts describe the application and equipment category, not a performance grade or marketing label. Check the standard text and local codes for each installation rather than assuming them from a catalogue headline.
Cutter mechanism versus vortex impeller
A cutter or macerator system places a high-speed stainless steel cutter at the inlet. As toilet effluent enters, the rotating blades reduce long fibres and solids to fine particles that leave with the water. Because the solids are ground down, discharge can run in small-bore pipe, typically Ø32 mm or Ø40 mm. That helps in retrofit work: small holes are easier to core through basement walls and the run can be concealed. It is the usual choice when adding a bathroom to an existing building.
A vortex impeller with a large free passage works differently. The impeller sits recessed at the top of the chamber and induces a strong vortex; solids and fibres are carried out with the swirl rather than struck by the blades, so the mechanism stays clear. Free passage reaches 35 mm to 50 mm. It suits laundry discharge, shower waste and manifolds where several fixtures share one unit, because textiles and hair are less likely to wrap around it.
Neither design is universally better: the cutter suits small-pipe retrofits, the vortex high-fibre, high-volume duty. Selection starts with the problem the site has.
Anteloy AT series: compact macerator pumps
The AT range covers blackwater duty from a single WC to a complete basement drainage. A separated motor and water chamber keeps the mechanical seal out of the wastewater, and a stainless steel anti-winding cutter head handles incoming solids. Protection class is IP55 for 450 W and above models, IP54 for the 300 W pair; insulation is Class F and running noise is below 45 dB. Start level and stop level are listed where specified.
| Model | Power input (P1) | Maximum flow | Maximum head | Protection class | Start level | Stop level |
|---|---|---|---|---|---|---|
| AT-C300A | 300 W | 100 L/min | 6.5 m | IP54 | 55 mm | 25 mm |
| AT-N300B | 300 W | 85 L/min | 6 m | IP54 | — | — |
| AT-C450A | 450 W | 125 L/min | 8 m | IP55 | 75 mm | 35 mm |
| AT-N450B | 450 W | 115 L/min | 8 m | IP55 | 75 mm | 35 mm |
| AT-C450C | 450 W | 125 L/min | 8 m | IP55 | 80 mm | 30 mm |
| AT-N450D | 450 W | 115 L/min | 8 m | IP55 | 80 mm | 30 mm |
| AT-C600A | 600 W | 150 L/min | 9.5 m | IP55 | — | — |
| AT-N600B | 600 W | 130 L/min | 9 m | IP55 | — | — |
| AT-C750A | 750 W | 165 L/min | 11 m | IP55 | — | — |
| AT-N750B | 750 W | 150 L/min | 11 m | IP55 | — | — |
| AT-N900B | 900 W | 170 L/min | 12 m | IP55 | — | — |
Read the table as a progression. The 300 W pair suits a single basement WC; the 450 W models cover a main bathroom with WC and basin, including wall-hung configurations. The 600 W pair handles a full bathroom with WC, shower and basin, and the 750 W models suit deeper basements and longer runs. AT-N900B is the high-flow, high-head option for North America.
Check voltage and frequency against the market before stocking: AT-N900B is the 110 V, 60 Hz variant.
Anteloy AT-S series: PE lifting stations
For greywater and light commercial drainage, the AT-S range uses a seamless, corrosion-resistant polyethylene tank with an IP68 pump. Level control pairs a pneumatic pressure switch with a float.
- AT-S25 and AT-S50 — single-pump stations with 25 L and 50 L tanks. Power input (P1) is 750 W or 1100 W, maximum flow 27–32 m³/h, maximum head 11–13 m, free passage 35 mm. They suit basement laundry rooms, bar sinks and light greywater duty.
- AT-S60 — a 60 L single-pump station with 50 mm free passage, the same motors and a 27–32 m³/h flow range, for duty with more suspended matter.
- AT-S90 — a 90 L twin-pump station with alternating and parallel operation, 50 mm free passage and up to 120 starts per hour, aimed at multi-unit housing, clubs and public washrooms with continuous discharge.
Note the units: AT-S flow is in m³/h, AT flow in L/min — convert before comparing.
Wholesaler inventory and pre-sales guidance
Most field failures trace to selection mistakes that good pre-sales advice prevents. Three rules belong in every quote.
Do not mix grey into black. A small-passage greywater pump must not be recommended for a circuit that includes a toilet. Faecal matter and paper will foul the impeller or switch quickly, and the callout costs more than the price difference between the two pumps. If a site has a WC, specify a macerator or a station with the appropriate free passage.
Set expectations on wipes. AT pumps are designed for human waste and standard toilet paper. Tell contractors plainly that flushable wipes, feminine hygiene products and plastic bags can still wrap around the cutter and fall outside that design intent. A short note on the quote or installation leaflet reduces the most common misuse complaint.
Standardise the spare parts kit. The Anteloy accessory system — hose connectors, reducing sleeves, DN80 flange and plugs for multiple national standards — is designed for interchangeability across the range. Stocking a small set of standard accessories lets a distributor support installations across the 30+ export markets the brand serves, without a separate spares inventory for each model.
For a model-by-model cross-check against a fixture schedule, send the details through the quote form.
Working on a real project?
Send the fixture list, not the model code
Send the fixture list, required lift height and supply voltage. We will recommend the matching model from the 2026 catalog.
FAQ
Q: Can a greywater pump handle a toilet if the pipe is large enough? No. Pipe size does not change the fluid. A greywater unit lacks the cutting or solids-passing design that blackwater needs, so faecal matter and paper can foul the chamber and impeller. Match the pump to the fixture.
Q: What is the difference between EN 12050-1 and EN 12050-2? EN 12050-1 addresses equipment for wastewater containing faecal matter, while EN 12050-2 addresses wastewater without faecal matter. EN 12050-3 covers limited applications that also include faecal matter. They are application categories, not grades of performance.
Q: Which Anteloy series suits a basement with a shower, basin and washing machine but no toilet? A AT-S lifting station is the natural fit. Check maximum flow, maximum head and free passage against the fixture load, and use the m³/h figures for AT-S models.
Q: Why do AT flow figures use L/min while AT-S figures use m³/h? The two series are specified in the units used for their duty: compact macerators in litres per minute, larger PE stations in cubic metres per hour. Convert before comparing or you will mis-size the selection.
Related reading
- Macerator pump vs sewage lifting station — how the two system types differ in layout and duty.
- Effluent pump vs sewage pump — matching pump type to fluid class.
- What is free passage in a sewage pump? — why the opening size drives blockage resistance.