The first question is whether the tank is actually empty. If it is, the level control has failed; if it is not, the pump is not delivering. Two different repairs.
The first question to answer is not "why is the pump running" but "is the tank actually empty?" Those two situations look identical from the room — the pump runs continuously — and they have completely different causes. If the tank is empty and the pump still runs, the level control has failed. If the tank is not empty, the pump is running but not delivering, and the fault is in the hydraulics or the motor.
Answer that question and half the diagnosis is done.
Case A: the tank is empty but the pump runs
The pump is doing its job; the switch is not telling it to stop.
| Cause | How to confirm |
|---|---|
| Float stuck in the raised position | Lift the float by hand — it does not drop |
| Float contacts welded closed | Float moves but pump does not stop when it drops |
| Float fouled on pipework | Float visibly displaced or trapped |
| Pressure switch stuck | Pump continues with the level well below start level |
| Contactor stuck closed in the control panel | Panel stays energised after the float drops |
| Manual override left on | Check the panel switch position |
The immediate action is to isolate the power. A pump running dry destroys its mechanical seal within minutes, because the seal is cooled and lubricated by the pumped liquid.
The fix depends on which of the above it is. A stuck float is usually freed and repositioned. Welded contacts mean a replacement float. A stuck contactor means a replacement contactor. All are inexpensive relative to a pump.
For the float-specific version, see float switch stuck.
Case B: the tank is not empty and the pump runs
The pump is running but not moving the water. The list here overlaps with "runs but does not pump", with one addition — the pump may be moving some water, just not enough to keep up.
| Cause | How to confirm |
|---|---|
| Discharge blocked or valve closed | Discharge pipe cold and silent; check valve positions |
| Non-return valve stuck shut | Pump runs against dead head |
| Impeller partly blocked | Reduced flow, pump labours |
| Impeller worn | Flow has declined gradually over months |
| Wrong rotation (three-phase) | Flow far below rated, motor sounds normal |
| Air lock | Pump runs, no flow, low current draw |
| Discharge bore too small or route too long | Duty point beyond the pump's curve |
The distinguishing test: clamp the current.
- Normal current, no flow → blocked discharge or a closed valve.
- Low current, no flow → air lock or dry running.
- High current, no flow → mechanical binding or a pump pushed beyond its duty.
The full sequence is in sewage pump runs but does not pump water.
Case C: the tank empties and refills continuously
The pump is working correctly and the inflow genuinely exceeds it — or there is inflow that should not be there.
| Cause | How to confirm |
|---|---|
| A fixture is running continuously | A leaking cistern, a dripping tap, a running overflow |
| Groundwater entering the tank | Level rises with no fixtures in use; check for a high water table |
| Inlet pipe leaking into the tank | Water entering when nothing is running |
| Pump undersized for the actual inflow | Inflow measured exceeds the pump's rated flow |
| Two stations on one discharge line | One pumping into the other |
A leaking WC cistern is the most common and the least obvious. It delivers a steady trickle that the pump handles happily, cycle after cycle, all day. The station sounds fine and the water bill does not.
The test: with the pump off and nothing in use, watch the tank level for an hour. Any rise is inflow that should not be there.
Why continuous running matters
A pump that runs continuously is not just noisy. Three things degrade:
The seal. Mechanical seals rely on the pumped liquid for cooling and lubrication. Continuous running with intermittent dry periods — which is what happens when the pump outruns the inflow — wears the seal faster.
The motor. Continuous operation at high load accumulates heat. Most sewage pumps are not rated for 100% duty; the manufacturer's duty cycle figure tells you what they are designed for.
The float switch. A float that switches constantly wears its contacts, and on direct-switched stations it carries the motor current every cycle.
The result is a cascade: continuous running wears the float, the worn float causes erratic operation, and the erratic operation is what finally gets noticed.
Diagnostic order
- Is the tank empty? Look. This single observation splits the diagnosis.
- If empty → isolate power, check the float, then the contactor.
- If not empty → clamp the current and check the discharge.
- If neither → measure the inflow with the pump off.
- Check the duty cycle against the manufacturer's rating.
Prevention
| Check | Interval |
|---|---|
| Lift the float by hand and confirm it stops the pump | Monthly |
| Confirm no fixture is running continuously | Monthly |
| Check valve positions after any service | Every service |
| Measure inflow with the pump off | Annually |
| Inspect the contactor for pitting | Annually |
The monthly float test is the one that catches Case A before it destroys a seal.
Working on a real project?
Send the fixture list, not the model code
Send the fixture list, required lift height and supply voltage. We will recommend the matching model from the 2026 catalog.
FAQ
Why does my sewage pump keep running when the tank is empty? The level control has failed — a float stuck up, welded contacts, a stuck pressure switch or a stuck contactor. Isolate the power immediately; a pump running dry will damage its seal.
Why does my pump run but the tank stays full? The pump is not delivering: blocked discharge, a stuck non-return valve, a jammed or worn impeller, wrong rotation, or an air lock. Check the discharge first.
Is it normal for a sewage pump to run for a long time? Running for a few minutes to empty a full tank is normal. Running continuously with no sign of emptying is not.
Can a leaking toilet cause a pump to run constantly? Yes, and it is one of the most common causes. A cistern that trickles continuously delivers a steady inflow that keeps the pump cycling all day.
Next step
If the pump has failed and needs replacing, send the model code and installation details. We will confirm the replacement and whether the tank and connections can be reused.